ABB 1SFL547002R1311 AF265-30-11-13 Contactoris

Brevis descriptio:

Brand: ABB

Product nomen: Contactor

Exemplar: 1SFL547002R1311

 


Una e professionalibus FA One-subsistis praebitoribus in China. Nostra producta principalia possidet motorem, calcem planetarium, invertentem et PLC, HMI.Brands in iis Panasonicis, Mitsubishi, Yaskawa, Delta, TECO, Sanyo Denki, Scheider, Siemens. , Omron et etc.; Shipping time: Within 3-5 working days after getting the payment. Mercedem modo: T/T, L/C, PayPal, Unionis occidentalis, Alipay, Wechat et sic porro

Product Detail

Product Tags

General Information

Product Type:
AF265-30-11-13
Product ID:
1SFL547002R1311
EAN:
7320500481189
Catalogue Description:
AF265-30-11-13 Contactor
Longa Descriptio:
AF265-30-11-13 est polus III - 1000 V IEC vel 600 V UL contactor cum contactibus auxiliaribus prae-positis et Circuitus principalis Bars, motores moderantes usque ad 132 kW / 400 V AC (AC-3) vel 200 hp. / 480 V UL et mutandi potestas circuitiones usque ad 400 A (AC-1) vel 350 A UL usum generalem. Per technologiam AF technologiam, contactor amplam potestatem voltage range (100-250 V 50/60 Hz et DC habet), varias voltagenarum potestates magnas disponens, energiae consumptions minuens et operationes distinctas in instabili retiacula procurans. Praeterea, impetus in tutela aedificatur, solutionem pactam offerens. AF contactusorsi rationem generis stipitem habent, facile extendi possunt cum adiunctis in impedimentis contactus auxiliaribus et accessoriis amplis additis.

Dimensiones

Productum Net Latitudo:
140 mm
Productum Net Profundum / Longitudo:
180 mm
Product Altitudo Net:
225 mm
Product Net pondus:
3.9 kg

Technical

Contactus Main numerus NO:
3
Numerus Main Contactus NC:
0
Contactus auxiliares numero NO:
1
Numerus Notorum auxiliariorum NC:
1
Rated Operational intentione:
Circuitus principalis 1000 V
Rated Frequency (f);
Circuitus principalis 50 / 60 Hz
Conventional Free-air Scelerisque Current (Ith);
acc. ad IEC 60947-4-1, Aperi Contactores Θ = 40 °C 400 A
Rated Operational Current AC-1 (Ie);
(1000 V) 40 °C 350 A
(M V) 55°C CCC A .
(M V) LX°C CCC A .
(1000 V) 70°C 240 A
(690 V) 40 °C 400 A
(690 V) 55 °C 350 A
(690 V) 70 °C 290 A
Rated Operational Current AC-3 (Ie);
(415 V) 55 °C 265 A .
(440 V) 55 °C 265 A
(500 V) 55 °C 250 A
(690 V) 55 °C 250 A
(1000 V) 55 °C 113 A .
(380 / 400 V) 55 °C 265 A .
(220 / 230 / 240 V) 55 °C 265 A
Rated Operational Power AC-3 (Pe);
(415 V) 132 kW
(440 V) 160 kW
(500 V) 160 kW
(690 V) 200 kW
(1000 V) CLX kW
(380 / 400 V) 132 kW
(220 / 230 / 240 V) 75 kW
Rated Capacity AC-3:
8 x Ic AC-3
Rated Capacity AC-3
10 x Ic AC-3
Brevis circuitus Protective machinae:
gG Type Fuses D A
Rated breve tempus sustine Current Minimum intentione (ICW);
ad XL °F Temp in Ambient, in Free Air, ex re publica Frigidi 10 s 2120 A
in XL °F Ambient Temp, in Free Air, ex re publica frigida 15 min 400 A
in 40 °F Temp, in Free Air, ex re publica Frigidi 1 min 865 A
in 40 °F Ambient Temp, in Free Air, ex re publica Frigidi 1 s 2650 A
in 40 °F Ambient Temp, in Free Air, ex re publica Frigidi 30 s 1224 A
Maximum Capacitas Fractio:
cos phi=0.45 (cos phi=0.35 pro Ic> 100 A) ad 440 V 3800 A
cos phi=0.45 (cos phi=0.35 pro Ic> 100 A) ad 690 V 3300 A
Maximum Electrical Switching Frequency:
(AC-1) cyclos per horae CCC
(AC-2/AC-4);
(AC-III) cyclos per horae CCC
Rated Operational Current DC-1 (Ic);
(110 V) 2 Polonorum in Series, 40 °C 350 A
(220 V) 3 Polonorum in Series, 40 °C 350 A
Rated Operational Current DC-III (Ic);
(110 V) 2 Polonorum in Series, 40 °C 350 A
(220 V) 3 Polonorum in Series, 40 °C 350 A
Rated Operational Current DC-V (Ie);
(110 V) 2 Polonorum in Series, 40 °C 350 A
(220 V) 3 Polonorum in Series, 40 °C 350 A
Rated Insulation Voltage (Ui);
acc. ad IEC 60947-4-1 et VDE 0110 (Gr. C) 1000 V
acc. ad UL/CSA DC V
Rated Impetus resistendi intentione (Uimp);
Main Circuit 8 kV
Mechanica Durabilitas:
V decies
Maximum Mechanica Switching Frequency:
CCC circuitus per hora
Coil limites Operating:
(acc. to IEC 60947-4-1) 0.85 x Uc Min. ... 1.1 x Uc Max. (at θ ≤ 70 °C)
Rated Control Circuit Voltage (Uc);
50 Hz 100 ... 250 V
60 Hz 100 ... 250 V
DC Operatio 100 ... 250 V
Coil consummatio:
Lucreium apud Max. Rated Control Circuit Voltage 50 Hz 17.5 V·A
Lucreium apud Max. Rated Control Circuit Voltage 60 Hz 17.5 V·A
Lucreium apud Max. Rated Control Circuit Voltage DC 4.5 W
In at viverra max. Rated Control Circuit Voltage 50 Hz 385 V·A
In at viverra max. Rated Control Circuit Voltage 60 Hz 385 V·A
In at viverra max. Rated Control Circuit Voltage DC 410 W
Tempus agunt:
Inter Coil De-energiam et NO Contactum Oris 37 ... 47 ms
Inter Coil Energization et NO Contagium 25 ... 55 ms
Main Circuit capacitatem connectens:
Flexible 2 x 70 ... 185 mm²
Rigidum Al-Cable 1 x 185 ... 240 mm²
Rigidum Cu-Cable 2 x 70 ... 185 mm²
Circuitus Auxiliaris connectens capacitatem:
Flexibile cum Ferrule 2x 0.75 ... 2.5 mm²
Flexibile cum Insulato Ferrule 2x 0.75 ... 2.5 mm²
Flexibile 2x0.75 ... 2.5 mm²
Solidus 2 x 1 ... 4 mm²
1 x 1 .... 4 mm²
Gradus Praesidium:
acc. ad IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
acc. ad IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00
Terminatio Type:
Principalis Ambitus: Bars

Technical UL/CSA

NEMA Size:
5
Continua Current Rating NEMA:
270 A
Horsepower Rating NEMA:
(200 V AC) Tres Phase 75 Hp
(230 V AC) Tres Phase 100 Hp
(460 V AC) Tres Phase 200 Hp
(575 V AC) Tres Phase 200 Hp
Maximum Operating intentione UL/CSA:
Circuitus principalis 1000 V
General Usus Rating UL/CSA:
(600 V AC) 350 A
Horsepower Rating UL / CSA:
(200 V AC) Tres Phase 75 hp
(208 V AC) Tres Phase 75 hp
(220 ... 240 V AC) Tres Phase 100 hp
(440 ... 480 V AC) Tres Phase 200 hp
(550 ... 600 V AC) Tres Phase 250 hp

Environmental

Ambiens Aeris Temperature:
Prope Contactorem aptum cum Thermal O/L Nullam (0.85 ... 1.1 Uc) -25 ... 50 °C
Prope Contactorem sine Thermal O/L Nullam (0.85 ... 1.1 Uc) -40 ... 70 °C
Prope Contactorem pro at -40 ... 70 °C
Maximum Operating Altitudo Licet:
Sine Derating MMM m

Material Obsequium

Conflictus mineralium Reporting Formula (CMRT);
SPATIUM Declaratio:
RoHS Information:
RoHS Status:
Post EU Directivum 2011/65/EU et Emendationem 2015/863 die 22 Iulii, 2019
Substantiae toxicae Control Act - TSCA:
WEEE B2C/B2B;
Negotium Ad Negotia
WEEE Category:
5. Parvus Equipment (Nulla ratio externa plusquam L cm)

Valorem circularem

ABB EcoSolution:
Ita
Principia Recyclability Rate Design Circularis:
Design for Closing Resource Loops - Standard EN45555 - 76.3 %
Finis vitae Instructiones:
Group vastum ad Landfill Target:
Vastum non-anceps ad landfill mittitur, ubi nulla alternatio optionis praesto est intra 100km facilitatis
Improved Resource Efficiency for Customers:
Product Efficiency - Productum magis industria efficax consideratum comparatur ad similes productos in mercatu vel productos ex eadem linea
Material content sustinebilis:
Recycled Metal - 33 %

  • Previous:
  • Next: