Una e professionalibus FA One-subsistis praebitoribus in China. Nostra producta principalia possidet motorem, calcem planetarium, invertentem et PLC, HMI.Brands in iis Panasonicis, Mitsubishi, Yaskawa, Delta, TECO, Sanyo Denki, Scheider, Siemens. , Omron et etc.; Shipping time: Within 3-5 working days after getting the payment. Payment modo: T/T, L/C, PayPal, Unionis occidentalis, Alipay, Wechat et sic porro
Spec Detail
Servo amplificator exemplar MR-JE- | 10A | 20A | 40A | 70A | 100A | 200A | 300A | |
Output | Rated voltage | III-PSE 170 V AC | ||||||
Ratum current[A] | 1.1 | 1.5 | 2.8 | 5.8 | 6.0 | 11.0 | 11.0 | |
Potentia copia initus | Voltage/frequency(Note 1) | III-phasis seu I-phasis 200 V AC ad 240 V AC, 50 Hz/60 Hz | III-phasis seu I-phasis 200 V AC ad 240 V AC, 50 Hz/60 Hz(Note 9) | 3-phase 200 V AC ad 240 V AC, 50 Hz/60 Hz | ||||
Ratum currentNota VII.[A] | 0.9 | 1.5 | 2.6 | 3.8 | 5.0 | 10.5 | 14.0 | |
Licet voltage fluctuatio | III-phasis seu I-phase 170 V AC ad 264 V AC | III-phasis seu I-phase 170 V AC ad 264 V AC(Note 9) | 3-phase 170 V AC ad 264 V AC | |||||
Licet frequency fluctuatio | ±5% maximum | |||||||
Interface potentia copia | 24 V DC ± 10% (requiritur capacitas currentis: 0.3 A) | |||||||
Imperium modum | Sine unda PWM imperium/vena imperium modum | |||||||
Regenerativa tolerabilis potentia resistor-nativi aedificati(Note 2, 3).[W] | - | - | 10 | 20 | 20 | 100 | 100 | |
Dynamic fregit | inaedificata(Note 4, 8); | |||||||
Communicationis munus | USB: Iungo personalis computatrum (MR Configurator2 compatible) | |||||||
Encoder output pulsus | Compatible (A/B/Z-phase pulsus) | |||||||
Analog monitor | 2 canales | |||||||
Positio imperium modus | Maxime input pulsus frequency | 4 Mpulses / s (cum receptaculo differentiali utens), CC kpulses / s (cum usura collector aperto) | ||||||
Positioning feedback pulsus | Encoder resolution: 131072 pulses/rev | |||||||
Imperium legumen multiplicans factor | Electronic calces A/B multiplex, A: 1 ad 16777215, B: 1 ad 16777215, 1/10 <A/B < 4000 | |||||||
Positioning integram latitudinem occasum | 0 pulsus ad pulsus ±65535 (imperium pulsus unitas) | |||||||
Error nimis | ±3 conversiones | |||||||
Torque limit | Analogiam externam vel input (0 V DC ad +10 V DC/maximum torquem) constitue. | |||||||
Celeritas imperium modus | Celeritas imperium range | Analog celeritas imperium 1:000, interna celeritas imperium I: 5000 | ||||||
Analog celeritate imperium initus | 0 V DC ad ± X V DC / celeritas aestimata (Mobilitas ad X V mutabilis est cum [Pr. PC12]). | |||||||
Celeritas fluctuationis rate | ±0.01% maximum (0% ad C% onus fluctuatio), 0% (potentia fluctuatio: ± 10%) | |||||||
Torque limit | Analogiam externam vel input (0 V DC ad +10 V DC/maximum torquem) constitue. | |||||||
Torque imperium modus | Analog Aureus imperium initus | 0 V DC ad ± 8 V DC/maximum Aureum (input impedimentum: 10 kΩ ad 12 kΩ) | ||||||
Celeritas terminus | Analogia parametri vel extra initus posita (0 V DC ad ± X V DC/aestimanda velocitate) | |||||||
Positioning modus | Mensa punctum modum, programma methodus | |||||||
Servi munus | Provectus vibratio suppressionis imperium II, colum adaptivum II, robustum colum, autocinetum, tuning unum tactum, munus durum coegi, munus commentariis agitare, munus apparatus diagnosis, munus vigilantia potentia | |||||||
Munera tutela | Overcurrent shut-off, regenerative overvoltage shut-off, overload shut-off (electronic thermal), servo overheat protect protection, encoder error protection, regenerative error protection, undervoltage protection, instantaneae power defectum protection, overspeed protection, error nimio praesidio. | |||||||
Obsequio ad global signa | Refer ad "Conformitatem cum signis et ordinationibus global" in catalogo. | |||||||
Structura (IP rating) | Naturalis refrigeratio, aperta (IP20) | Vis refrigerandi, aperta (IP20) | ||||||
Proxima adscendens(Note 5) | III-tempus potentia copia initus | Possibile | ||||||
I-tempus potentia copia initus | Possibile | Non potest | - | |||||
Environment | Ambiens temperatus | Operatio: 0 ad 55 (non congelatio), repositio: -20 ad 65 (non-congelantia) | ||||||
Ambiens humiditas | Operatio / PRAECLUSIO: XC% RH maximam (non-condensationem) | |||||||
Ambience | Domesticas (no directo sole); non mordax gas, inflammabilis gas, oleum caligo vel pulvis | |||||||
altitudo | M m gradu minusve supra mare | |||||||
Repugnantia vibratio | 5.9 m/s2ad X Hz ad 55 Hz (directiones axium X, Y et Z) | |||||||
Mass [kg] | 0.8 | 0.8 | 0.8 | 1.5 | 1.5 | 2.1 | 2.1 |
De Renault Vel Servo Coegi:
1. Ratum output et celeritas motoris servo applicatur cum servo amplificante, cum motore servo coniuncto, intra determinatam potestatem copiam intentionis et frequentiae operatur.
2. Optionem regenerativam aptissimam elige pro systemate tuo cum programmate delectu nostro facultatem.
3. Refer ad "Optionem Regenerativam" in Catalogo pro potentia regenerativa tolerabili [W] cum optio regenerativa adhibetur.
4. Cum constructo in dynamico usu confregit, refer ad "MR-JE-_A Servo Amplificatoris Manualis Instructionis" licitum est onus inertiae motoriae rationi.
5. Cum servi ampliatores arcte ascendunt, temperaturam ambientem intra 0℃ ad 45 servant, vel cum 75% minusve oneris effectivi ratione utere.
6. RS-422 munus communicationis praesto est cum servo amplificorum factorum Kalendis Decembris 2013 vel serius. RS-485 munus communicationis praesto est cum servo amplificorum factorum Kalendis Maiis MMXV vel postea.
7. Huius valoris applicatio est cum copia potentiae 3-aetatis adhibetur.
8. Spatium orae maritimae per motum dynamicum fregit HG-KN/HG-SN servo motoris seriei a priore HF-KN/HF-SN diversum esse potest. Contactus tua localia venditio officii pro magis details.
9. Quando 1-phasis 200 V AC ad 240 V AC potentiae copia adhibita est, illis utere cum 75% minusve oneris effectivi ratione.
10. Compatible cum Mitsubishio-protocollo generali AC servo protocollo (RS-422/RS-485 communicatio) et protocollo MODBUS® RTU (RS-485 communicatio).