Omron Hot sale PLC moduli CPU unitas moduli CJ1M-CPU13-ETN

Description:

• Foedus 90 65 mm (H D) dimensiones primae classis in industria sunt.

• SYSMAC CJ-series CPU Unitas cum functione unitatis Aer.

• CPU elementum functionis eandem functionem habet ac CJ1M-CPU11/12/13.Usus efficax permittit applicationes legatorum.


  • MALITIA Price:US $0.5 - 9,999 / Piece
  • Min.Order Quantitas:100 Piece/Picies
  • Facultates copia:(X) Piece / Mass per mense
  • Una e professionalibus FA One-subsistis praebitoribus in China. Nostra producta principalia possidet motorem, calcem planetarium, invertentem et PLC, HMI.Brands inter Panasonic, Mitsubishi, Yaskawa, Delta, TECO, Sanyo Denki, Scheider, Siemens. , Omron et etc.;Shipping time: Within 3-5 working days after getting the payment.Payment modo: T/T, L/C, PayPal, Unionis occidentalis, Alipay, Wechat et sic porro

    Product Detail

    Product Tags

    Sichuan Focus Technology Co., Ltd.

    Habemusplus quam X annos experientiain productis in agro industrialis automation!Nos maxime focus inindustriae automation products, ut servo motore, PLC, HMI, frequentia variabilis Coegi, circumiens confractores, contactores, surgeprotector, thermostat, encoder, dispositos, et IGBT!Our automation products have been exported toplus quam L regionibuset regiones!

    Habemus nostrumproprium notam focusac etiam arctam ac diuturnam cooperationem cum aliis notis notis!Propter nostrumsummus qualitasy, competitive pretiumetieiunium partusplurimum e nostris clientibus suis foro succedentibus adiuvimus!Constanter nosmetipsos emendare debemus ut pluribus necessitatibus clientium conveniamus!

    Spec Detail

    Item Specifications
    Imperium modum Progressio stored
    I / O modum imperium Scan cyclici et processus immediati ambo possibilis sunt.
    Programmatio Linguae Scala Logica (LD), Sequential Function Charts (SFC), Textus Structured (ST), et
    Mnemonic.
    CPU processus modus Normalis Modus seu Peripheral Service prioritate Modus
    Instructio longitudinem I ad VII gradus per disciplinam
    scalae instructiones Proxime.CD (munus digiti 3-codes)
    Supplicium
    tempus
    Basic instructions 0.10 μs min.
    Specialis
    instructiones
    0.15 μs min.
    Supra tempus CJ1M-CPU12-ETN/CPU13-ETN: 0.5 ms min.
    CJ1M-CPU11-ETN: 0.7 ms min.
    Unitas nexum modum Nulla Backplane: Unitates directe inter se connexae.
    Adscendens modum DIN Track (conscendens stupra non potest)
    Numerus maximus
    connectable Unitates
    Summa 19 Unitates, inter 9 Unitates in CPU Rack et 10 Unitates in una Expansion
    Eculeus.
    (Constructum-in portu Aer- netis in CPU Unit e foraminibus 0 collocari debet, et est
    velut unus Unit.)
    Maximus numerus Expansion
    Tormenta
    CJ1M-CPU13-ETN: 1 max.(An EGO / O Imperium Unit non requiritur in CPU Rack et
    an I / O Interface Unit non requiritur in Expansion Rack).
    CJ1M-CPU11-ETN/12-ETN: Expansio fieri non potest.
    Numerus operum 288 (officia cyclica: 32, opera interrumpere: 256);
    Cum CJ1-H vel CJ1M CPU Unitates, munera interrumpere definiri possunt opera cyclica
    vocavit extra cyclica negotia.Haec inter cyclica usque ad 288 negotia adhiberi possunt.
    Officia cyclica singula cycli exercentur et reguntur cum TKON (820) et
    TKOF (821) instructiones.
    Nota 1 .
    Sequentia 4 genera operum interrumpentium sustentantur.
    Nota II.
    Potentia off interrumpenda negotia: 1 max.
    Scheduled pensa interregem: 2 max.
    I/O opera interregem: 32 max.
    Interpellare externa opera: 256 max.
    Interpellare types Obloquitur: Interrumpit generatur ad tempus horarium a CPU Unitates
    structa in timer.
    I/O Interrumpit: Interrupts from Interrupt Input Unitates.
    Potentia Off Interrupts (Vide nota): Interrumpit supplicium cum CPU Unitates potestatem
    est off.
    Externus I/O Interrumpit: Interrumpit e Speciali I/O Unitates vel CPU Bus Unitates.
    Nota: Non subnixa cum CJ1W-PD022 potentiae copia Unita annectitur.
    Vocatis subroutines ex more
    quam negotium
    Subroutines (globale subroutines appellatur).
    CIO
    (Core I/O)
    Area
    I / O Area 2,560: CIO 000000 ad CIO 015915 (160 verba e CIO 0000 to .).
    CIO 0159)
    Occasio verbi primi mutari potest ex defectu (CIO
    0000) ut adhiberi possit CIO 0000 ad CIO 0999.
    I/O frena collocantur Basic I/O Unitates.
    CIO Area
    potest esse
    ut opus bits
    si autem bits
    non usus est
    hic ostenditur.
    Link Area 3,200 ( verba 200): CIO 10000 ad CIO 119915 (verba CIO 1000 to .).
    CIO 1199)
    Vincula nexus pro data nexus adhibentur et in Unitates collocantur
    Controller Link Systems.
    CPU bus Unit Area 6,400 (verba 400): CIO 150000 ad CIO 189915 (verba CIO 1500 to .).
    CIO 1899)
    CPU Bus Unit frena reponunt statum operantem CPU Bus Unitates.
    (25 words per Unit, 16 Unitates max.)
    Specialis I / O Unit
    Area
    15,360 (verba 960): CIO 200000 ad CIO 295915 (verba CIO 2000 .);
    ad CIO 2959)
    Specialis I/O Unitas frena partita sunt Speciali I/O Unitates.(X words
    per Unit, 96 Unitates max.)
    Vide PLC Link
    Area (CJ1M CPU
    Unitates tantum)
    1,440 (verba 90): CIO 310000 ad CIO 318915 (verba CIO 3100 to .).
    CIO 3189)
    DeviceNet Area 9,600 (600 verba): CIO 320000 ad CIO 379915 (verba CIO 3200 to .);
    CIO 3799)
    DeviceNet frena partita servis pro DeviceNet Unit remotis
    I/O communications cum Magister usus est munus fixis
    prouinciis.
    Certa destinatio occasum I " Outputs: CIO 3200 ad CIO 3263
    Inputs: CIO 3300 ad CIO 3363
    Certa destinatio occasum II " Outputs: CIO 3400 ad CIO 3463
    Inputs: CIO 3500 ad CIO 3563
    Certa destinatio occasum III " Outputs: CIO 3600 ad CIO 3663
    Inputs: CIO 3700 ad CIO 3763
    Munus Magistri sequentia partita sunt
    cum DeviceNet Unit ut Servus adhibetur.
    Certa destinatio occasum I " Outputs: CIO 3370 (Servus magistro)
    Inputs: CIO 3270 (Magister servus)
    Certa destinatio occasum II " Outputs: CIO 3570 (Servus magistro)
    Inputs: CIO 3470 (Magister servus)
    Certa destinatio occasum III " Outputs: CIO 3770 (Servus magistro)
    Inputs: CIO 3670 (Magister servus)
    Internus I / O Area 4,800 partem (300 verba): CIO 120000 ad CIO 149915 (verba CIO 1200 ad CIO 1499);
    37,504 verba (2,344): CIO 380000 ad CIO 614315 (verba CIO 3800; CIO 6143);
    Haec frena in CIO Area adhibentur ut frena laboris in programmatione moderandi
    programma executionis.Ad externum adhiberi non possunt I/O.
    Area Opus 8,192 bits (512 words): W00000 ad W51115 (W000 ad W511)
    Programs modo moderatur.(I/O ab externa I/o terminals non potest).
    Nota: Cum frenis in programmando uteris, frenis utere in Area Laboris prima
    bits ex aliis locis ante usura.
    Area tenentes 8,192 bits (512 verba): H00000 ad H51115 (H000 ad H) frena tenens sunt ad
    exsecutionem programmatis moderari, et DE/OFF statum suum conservare cum
    PLC declinatur seu modus operandi mutatur.
    Nota: Munus Clausus obtinens Area verba ab H512 ad H1535 partita sunt.
    Haec verba non possunt esse nisi ad munus obstructionum exempli area (interne
    variabilis area collocari).
    Auxiliaris Area Lege modo: 7.168 frena (448 verba): A00000 ad A44715 (verba A000 ad A447)
    Legere/scribere: 8,192 frena (512 verba): A44800 ad A95915 (verba A448 ad A959)
    Frena auxiliaria certae functiones sortiuntur.
    Tempus Area XVI bits (TR0 ad TR15)
    Temporaria frena sunt ad tempus reponere DE/OFF supplicium conditionibus ad
    programma calami.
    Timor Area 4,096: T0000 ad T4095 (pro timers tantum)
    Contra Area 4,096: C0000 ad C4095 (pro calculis tantum)
    DM Area 32 Kwords: D00000 ad D32767
    Usus generalis propositi data area ad legendum et scribendum notitia in verbo unitates (16
    frena).Verba in DM Area conservant statum suum cum PLC inflexit vel
    operandi modus mutatur.
    Internum Praecipuum I/O Unit DM Area: D20000 ad D29599 (100 verba 96 Unitas)
    Solebant parametri constituere pro Speciali I/O Unitates.
    CPU bus Unit DM Area: D30000 ad D31599 (C verba 16 Unitas)
    Solebant parametri CPU bus Unitates collocare.
    EM Area Nullus
    Index Registers IR0 ad IR15
    Copia PLC memoria inscriptionum pro indirecta inscriptione.Index registri adhiberi potest
    independently in unaquaque re opus.
    Unius registri 32 frusta est (2 verba).
    Ponere ut indicem tabularum sive independenter in unoquoque negotio vel ad ea communicemus
    inter opera.
    Negotium Vexillum Area 32 (TK0000 ad TK0031)
    Negotium vexilla leguntur-tantum vexilla quae DE cum cyclico respondente opus est
    exsecutabile ac ON cum correspondentes munus non est exsecutabile aut in standby
    videri.
    Trace Memoria 4,000 verba (trac data: 31 bits, 6 words)
    Tabularium Memoria Memoria Card: Foedus mico chartarum memoria adhiberi potest (MS-DOS format).
    OMRON Memoria Cards adhiberi potest.

  • Priora:
  • Deinde: